LIMS Filter | CAL3K Features

LIMS Filter Another useful feature of the CAL3K Calorimeters The LIMS output on the D1 port can be filtered to EXCLUDE certain types of results. the exclusion must be enabled in the SYSTEM DEFINITION (accessed via any other port). SYSTEM DEFINITION : ‘NO LIMS CALIBR.’ Setting this option excludes any …

Access Levels

Access Levels Not everyone is the same and not all laboratories operate on the same guidelines. We have tried to make the CAL3K as flexible as possible and in return introduced complexity. 1 The following information applies to the : CAL3K-AP , CAL3K-A Not everyone is the same and not …

Air Cooler

Air Cooler The cooler 3K-2 can be controlled from the CAL3K or via the USB port at the rear. 1 The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F The cooler 3K-2 can be controlled from the CAL3K or via the USB port at the rear. …

Event Log

Event Log The CAL3K has a powerful event log. Every time something changes the Date/Time and value is logged into a circular buffer of approx. 6000 events. 1 The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F The CAL3K has a powerful event log. Every time …

Automatic Oxygen Filling

Automatic Oxygen Filling The CAL3K_AP is connected to the oxygen supply and will FILL the vessel automatically. It will also DEFLATE the vessel. 1 The following information applies to the : CAL3K-AP The CAL3K_AP is connected to the oxygen supply and will FILL the vessel automatically. It will also DEFLATE …

Heat Capacity

Heat Capacity The Heat capacity is a measurement which describes the amount of energy (heat) needed to raise the vessel temperature by 1 degree. 1 The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F. The Heat capacity is a measurement which describes the amount of energy …

Help

Help The HELP display is provided in two stages. Here’s how… 1 The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F. The CAL3K has a help function built in. It is accessible with the F10 key. The help display is supposed to give in any situation …

Load The Manual Vessel

Load the Manual Vessel Traditionally the apparatus is called a ‘BOMB CALORIMETER’, because the combustion cylinder looks like a ‘bomb’. 1 The following information applies to the : CAL3K-A , CAL3K-U, CAL3K-F. A word about ‘VESSEL’ and ‘BOMB’. Traditional the apparatus is called a ‘BOMB CALORIMETER’, because the combustion cylinder …