PC Setup File Operations

The following information applies to the : CAL3K-AP , CAL3K-A, CAL3K-U, CAL3K-F. The PC software includes a method by which a parameter or a calibration can be changed via a ‘File’. This File is a small internet friendly text file and it can be executed by the CAL3K software. To …

Calibration Management

The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F The CAL3K Vessel has 7 chassis/mode fields and each field can hold up to 10 calibrations. If more calibrations are performed then the oldest is overridden and replaced with the latest. These 10 fields are used with …

Connect a PC to the CAL3K

The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F The CAL3K has three ports to connect a PC or laptop to. These ports are: USB. Distance approx. 2 meters. Ideally suitable for laptops. A USB cable is supplied in the 3K-1-KT (USBCABAB). RS232 DATA D1 Port. …

Firing Conditions

The following information applies to the : CAL3K-AP , CAL3K-A , CAL3K-U, CAL3K-F. The firing conditions are contained in the DEFAULT parameters and operating MODES if applicable. In general terms the firing conditions are fixed by the factory in the default settings. Only the CAL3K-A and CAL3K-AP have an “EXPERIMENTAL” …

IntelCal System Calibration

The following information applies to the : CAL3K-AP , CAL3K-A, CAL3K-U, CAL3K-F. The CAL3K system uses two calibrations: Keyboard calibration, in real time, one sample, average with last ‘n’ calibrations PC calibration, in retrospect, multiple samples The PC calibration is called ‘IntelCal’ because of its complexity and system effectiveness. The …

Max and Stats

The following information applies to the : CAL3K-A, CAL3K-AP, CAL3K-U, CAL3K-F. The CAL3K keeps the following Maximum and statistical data: Maximum Vessel Start temperature, Date & Time Maximum Vessel temperature, Date & Time Maximum Ambient temperature, Date & Time Maximum Pressure (CAL3K-AP) In this chassis Firings Calibrations Miss Fires Vessel …

Max and Stats (CAL3K-AP)

The following information applies to the : CAL3K-AP, CAL3K-A, CAL3K-U, CAL3K-F The CAL3K_AP keeps the following Maximum and statistical data: Maximum Pressure, Date & Time (CAL3K-AP) Maximum Vessel Start temperature, Date & Time Maximum Vessel temperature, Date & Time Maximum Ambient temperature, Date & Time In this chassis Firings Calibrations …

Ports

The following information applies to the : CAL3K-AP , CAL3K-A, CAL3K-U, CAL3K-F. The CAL3K has four communication ports for connecting to the outside. These ports are: USB 2.0 Prime access port, short distance, no restrictions DATA#1 RS232, 1.2 – 115.2Kb, 10-30 meter distance DATA#2 RS232, 115.2Kb, 10-30 meter distance (BALANCE …